Check Components - Henny Penny FlexFusion FPG-221 Maintenance Instruction

Gas platinum combi incl. grease collection
Table of Contents

Advertisement

Inspecting the permanent connection for visible damage
Test criteria
• Electrical connection line is installed correctly.
• Wire insulation is undamaged (not brittle or scorched).
Check USB connector for visible damage
Test criteria
• Conductor insulation is undamaged (not brittle).
Action
• Close the control panel (see "Opening and closing the control panel").

8.12 Check components

Checking fan
Test criteria
• Both fans work perfectly when the cooking process is
active.
If No
Troubleshooting according to service manual.
Check lift magnet air inlet flap
Test criteria
• Lift magnet works perfectly.
If No
Troubleshooting according to service manual.
Inform operator.
Check the steaming unit (see service level)
Test criteria
• Humidification unit works perfectly.
• Water volume measured in the DynaSteam test indi-
cated.
Unit in "ml" or "fl oz".
If No
Troubleshooting according to service manual.
Check solenoid valve vapour release (service level / relay test)
Test criteria
• Solenoid valve works perfectly.