Henny Penny FlexFusion FPG-221 Maintenance Instruction page 35

Gas platinum combi incl. grease collection
Table of Contents

Advertisement

Checking for leaktightness outside the unit
Test criteria
• Gas-carrying parts tight (see "Checking tightness out-
side the device").
• Does the information on the gas type supplemental label match the gas type available?
• Information from the gas type supplemental label entered?
natural gas E/H, G20, 8 inch WC (20 mbar)
• Is the unit connected with cable protection device for gas line?
• Dimension of Gas Supply Line Connection "I.D." at the unit:
• Dimension of Gas Supply Line at the wall:
• Is the gas connection line leak-free?
• Are gas-conducting parts inside the unit leak-free?
Gas type
Natural gas A
LP Gas B/P gas E
Connection pressure OK (right side port on gas valve "a")?
• Is the connection pressure (dynamic pressure) OK at "High" power? (See chapter "Checking the con-
nection pressure" in the installation instructions)
Connection pressure (dynamic pressure):
• Exhaust gas values at full load "High" okay? (See chapter "Checking exhaust gas values at partial
load" in the installation instructions)
Measured CO
:
2
Measured CO:
ppm
Gas connection
liquid gas P, G31, 12 inch WC (30 mbar)
inch
inch
Dynamic pressure (inch WC
(mbar))
8 (20)
12 (30)
Gas connection
Set CO
2
Vol %
%
Set CO:
Maintenance instructions
Performing maintenance
Remarks / values
Dynamic pressure range (inch WC
(mbar))
6.8 - 10 (17 - 25)
17 - 23 (42.5 - 57.5)
a
:
Yes
No
Yes
No
Yes
No
Vol
ppm
35