Function Test Grease Separator; Function Test Automatic Flushing - Henny Penny FlexFusion FPG-221 Maintenance Instruction

Gas platinum combi incl. grease collection
Table of Contents

Advertisement

Performing maintenance
Clean grease collection system
Test criteria
• Grease collection system has been cleaned.

8.17.2 Function test grease separator

Check grease trap
Test criteria
• Water / grease is pumped into the collection container.

8.17.3 Function test Automatic flushing

Prerequisite
38
Flush the system for approx. one minute.
Cleaning is complete.
Disconnect the water hose from the grease drain hose.
Detach the grease drain hose from the grease collector.
Mount the backflush fitting on the grease drain hose.
Open the cooking chamber door.
Remove tray trlley
Spray water into the cooking chamber with the hand shower for at
least 30 seconds.
Open the relay test in the service menu.
Activate relay K13. The grease pump switches on.
Water/grease is pumped into the collection container = pump
system in order.
Water/grease is not pumped into the collection container = carry
out troubleshooting.
Tap "K 13" to exit.
Detach the grease drain hose from the grease collector.
Mount the backflush fitting on the grease drain hose.
Open the cooking chamber door.
Remove tray trlley
Open the relay test in the service menu.
Activate relay K14.
Solenoid valve K41 for flushing is switched on.
After approx. 30 seconds, additionally activate relay K13.
Water is pumped into the collection tank = solenoid valve OK.
Water and occasional lumps of grease are pumped into the
collection container = clean the grease drainage system. Then
repeat the test.
Water is not pumped into the collection tank = carry out
troubleshooting.
Maintenance instructions
Remarks / values
Remarks / values
Yes
No
Yes
No

Advertisement