Check water inlet in the cooking chamber for limescale residues
Test criteria
• Water inlet is free of limescale residues.
Check water inlet in the cooking chamber for limescale residues
Test criteria
If No
Decalcify or replace water inlet pipe.
8.7 Check Water Connection
Checking the flexible hose line on the unit
Test criteria
• Flexible hose line is tight (no deposits or corrosion).
If No
Change flexible conduit.
8.8 Check Gas Connection
Check gas connection line
Test criteria
• Firm fit with no damage, creases, or exposure to external heat sources.
In case of no.
•
Inform the operator: The device must not be operated
in a defective condition.
•
Do not carry out any further work.
•
Complete or schedule repair work.
Check external exhaust hood
Test criteria
• External exhaust hood is operational.
If no,
Inform store manager.
8.9 Check Flexible Hose Lines
Check the flexible hose line in the unit
Test criteria
• Clamps are screwed on tightly.
If No
Tighten bolts or replace clamp.
Maintenance instructions
Performing maintenance
Remarks / values
Remarks / values
Remarks / values
Remarks / values
Remarks / values
Remarks / values
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
31