Operation; Prestart Checklist - Kohler KD700 Operation

Industrial generator sets
Table of Contents

Advertisement

2.1

Prestart Checklist

To ensure continued satisfactory operation, perform the following checks or inspections before or at each startup, as designa ted,
and at the intervals specified in the service schedule. In addition, some checks require verification after the unit starts.
DANGER
Air Cleaner. Check for a clean and installed air cleaner element to prevent unfiltered air from entering engine.
Air Inlets. Check for clean and unobstructed air inlets.
Battery. Check for tight battery connections. Consult the battery manufacturer's instructions regarding battery care and
maintenance.
Coolant Level. Check the coolant level according to the cooling system maintenance information.
Note:
Block Heater Damage. The block heater will fail if the energized heater element is not immersed in coolant. Fill the cooling
system before turning on the block heater. Run the engine until it is warm, and refill the radiator to purge the air from the system
before energizing the block heater.
Drive Belts. Check the belt condition and tension of the radiator fan, water pump, and battery charging alternator belt(s)
according to the drive belt system maintenance information.
Enclosure Doors, if equipped. Check that the service access doors are closed and secured. Leaving the doors open will create
excessive noise.
Exhaust System. Check for exhaust leaks and blockages. Check the silencer and piping condition and check for tight exhaust
system connections.
Inspect the exhaust system components (exhaust manifold, exhaust line, flexible exhaust, clamps, silencer, and outlet pipe) for
cracks, leaks, and corrosion.
Check for corroded or broken metal parts and replace them as needed.
Check for loose, corroded, or missing clamps and hangers. Tighten or replace the exhaust clamps and/or hangers as
needed.
Check that the exhaust outlet is unobstructed.
Visually inspect for exhaust leaks (blowby). Check for carbon or soot residue on exhaust components. Carbon and soot
residue indicates an exhaust leak. Seal leaks as needed.
Fuel Level. Check the fuel level and keep the tank(s) full to ensure adequate fuel supply.
Controller Check. Touch the controller screen to verify that it turns on. The controller screen dims automatically after a period
of time with no activity.
Oil Level. Maintain the oil level at or near, not over, the full mark on the dipstick.
Operating Area. Check for obstructions that could block the flow of cooling air. Keep the air intake area clean. Do not leave
rags, tools, or debris on or near the generator set.
Radiator. Check that the radiator fins and air inlets/outlets are clean of leaves, insects, dirt, and other debris. Use compressed
air to clear the obstructed passages as needed.
TP-7070
11/22
Hazardous voltage. Moving parts.
Will cause severe injury or death.
Operate the generator set only when all guards and electrical enclosures are in place.
Section 2. Operation
23

Advertisement