Installing the Agent Greeting Card
On new Option 51C to 81C Meridian 1 systems (including and after IPE Shelf
vintage NT8D37EC) any IPE slot can be used to house the Agent Greeting card. On
older Option 51C to 81C Meridian 1 systems, by default, only slots 0, 4, 8, and 12
can be used for Agent Greeting cards, as these are fully wired on the IPE shelf
backplane. If the card is placed in any other slot, an NT8D81AA Backplane to I/O
Panel cable must be installed to connect all the required signals to the I/O panel.
See Figure 4 and Figure 5 for cabling the Agent Greeting card.
The NTMF94BA cable is secured to the I/O panel using a screw and a cable tie.
B ac kpla ne
co nn ec tor
On the NT8D37EC shelf (see Figure 4), the backplane connectors L1, L2, and L3
from each card slot, cable to an I/O connector. With the NT8D37EC shelf, an Agent
Greeting card works in any card slot from 0 to 15.
NTPH13AA_Install

Figure 4: NT8D37EC shelf cabling

NT8D81AA
1
1
1
1
2
2
2
2
3
3 3 3
3.02 September 2006