Setting Conditions For The Gr2000 B - Hitachi GR2000-B Series Installation Manual

Hide thumbs Also See for GR2000-B Series:
Table of Contents

Advertisement

2.2

Setting Conditions for the GR2000 B

Table 2-1 below shows the physical specifications of the GR2000-B. This table
outlines the basic conditions required to install the GR2000-B models. Users should
place the devices in the environment where all of the following conditions are
satisfied.
Table 2-1
Item
Dimensions (W x D x H)
Weight
Input voltage
Frequency
Input power required
Quantity of heat generated (max)
Noise (Note 1)
Vibration
Dust (Note 2)
Temperature while running
Temperature while not running
Temperature while in storage
Humidity while running
Humidity while not running
Humidity while shipping or in storage
Note 1:
This should be checked 1 m away from the side panel of the unit.
Note 2:
Based on the measurement of falling dust (see section 2.6 on page 2-5).
GR2K-GA-0007
Rev. 5.00
Physical Specifications for the GR2000-B Series
GR2000-1B
6 kg
170 VA
150 W
Specification
GR2000-2B
GR2000-2B+
435 x 380 x 44 mm
7 kg
Single phase 100-120/200-240 VAC ±10%
50/60 ±1 Hz
190 VA
170 W
Below 45 dBm
2.45 m/s
Below 5%/W
0~40 deg. C
-10~43 deg. C
-25~60 deg. C
10~85% (no condensation)
8~85%
5~85%
Preparing for Installation
GR2000-BH
440 x 460 x 86
mm
16kg
300VA
260W
47dBà»â½
2-3