Replacing A Gbic; Detaching A Gbic; Attaching A Gbic - Hitachi GR2000-B Series Installation Manual

Hide thumbs Also See for GR2000-B Series:
Table of Contents

Advertisement

Hitachi Gigabit Router GR2000-B Series Installation Guide
5.5

Replacing a GBIC

You may add or replace the GBIC while keeping NEB1G-1B, NEBH1G-4C, or
NEBH1G-4E network interface boards inserted into a chassis with the power on.
Follow the procedures below when you want to replace the GBIC without switching
off the router.
5.5.1

Detaching a GBIC

Step 1.
Issue the following command from your operation terminal to stop
operation of the Ethernet port.
Note: For information about a slot/port number of a network interface, see "Chapter 1,
*
Component Overview."
Step 2.
If necessary, delete the appropriate configuration information.
Make sure that the indicator "GBIC DIS LED" on the NEB1G-1B, or the
Step 3.
"GBIC LED" on the NEBH1G-4C, or NEBH1G-4E, is lit in yellow and remove
the GBIC as in Section 4.7, "Attaching and Detaching the GBIC" on page
4-24.
5.5.2

Attaching a GBIC

Step 1.
Attach the GBIC to a network interface board by referring to Section 4.7,
"Attaching and Detaching the GBIC" on page 4-24.
Step 2.
Issue the following command from your operation terminal to start
operation of the Ethernet port.
Note: For information about a slot/port number of a network interface, see "Chapter 1,
*
Component Overview."
Step 3.
If necessary, add the appropriate configuration information.
5-12
Input form if using the new syntax operation commands:
close nif <nif_no> line <line_no>
Input form if using the old syntax operation commands:
maintenance close nif <nif_no> line <line_no>
where:
<nif_no>
: slot (0 or 1) of the target network interface
<line_no>
: port number of the targeted network interface
Input form if using the new syntax operation commands:
free nif <nif_no> line <line_no>
Input form if using the old syntax operation commands:
maintenance free nif <nif_no> line <line_no>
where:
<nif_no>
: slot (0 or 1) of the target network interface
<line_no>
: port number of the targeted network interface
GR2K-GA-0007