Maintaining The Mx5, Mx10, Mx40, And Mx80 Power Supplies And Cables; Maintaining The Mx5, Mx10, Mx40, And Mx80 Power Supplies - Juniper MX5 Hardware Manual

Universal routing platform
Hide thumbs Also See for MX5:
Table of Contents

Advertisement

MX5, MX10, MX40, and MX80 Universal Routing Platforms Hardware Guide
See Also

Maintaining the MX5, MX10, MX40, and MX80 Power Supplies and Cables

Maintaining the MX5, MX10, MX40, and MX80 Power Supplies

Purpose
Action
114
Frequent plugging and unplugging of fiber-optic cable into and out of optical
instruments can cause damage to the instruments that is expensive to repair. Instead,
attach a short fiber extension to the optical equipment. Any wear and tear due to
frequent plugging and unplugging is then absorbed by the short fiber extension, which
is easy and inexpensive to replace.
Keep fiber-optic cable connections clean. Small microdeposits of oil and dust in the
canal of the transceiver or cable connector could cause loss of light, reducing signal
power and possibly causing intermittent problems with the optical connection.
To clean the transceivers, use an appropriate fiber-cleaning device, such as RIFOCS
Fiber Optic Adaptor Cleaning Wands (part number 946). Follow the directions for the
cleaning kit you use.
After you clean an optical transceiver, make sure that the connector tip of the fiber-optic
cable is clean. Use only an approved alcohol-free fiber-optic cable cleaning kit, such
as the Opptex Cletop-S Fiber Cleaner. Follow the directions for the cleaning kit you
use.
MX5, MX10, MX40, and MX80 Modular Interface Card Description on page 43
MX5, MX10, MX40, and MX80 Modular Interface Card LEDs on page 57
Maintaining the MX5, MX10, MX40, and MX80 Power Supplies on page 114
Replacing an MX5, MX10, MX40, and MX80 AC Power Supply on page 115
Replacing an MX5, MX10, MX40, and MX80 AC Power Supply Cord on page 117
Replacing an MX5, MX10, MX40, and MX80 DC Power Supply on page 118
Replacing an MX5, MX10, MX40, and MX80 DC Power Supply Cable on page 122
For optimum router performance, verify the condition of the power supplies.
On a regular basis:
Check the status of the power supplies by issuing the
command. The output is similar to the following:
user@host> show chassis environment pem
PEM 0 status:
State
Temperature
DC Output:
PEM 1 status:
State
Temperature
DC Output:
show chassis environment pem
Online
OK
OK
Online
OK
OK
Copyright © 2019, Juniper Networks, Inc.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mx10Mx40Mx80

Table of Contents