Multitech MMH900 User Manual page 75

Mmh900 series statistical multiplexer
Table of Contents

Advertisement

conditions that affect the link's operation, such as
the downline load, modem type, flush timer value
and the response time setting.
Local MultiMux Composite Settings
INIATE DOWN
LINE LOAD TYPE
OFF
#RB
Status Report Baud Rate
This command sets the baud rate of the status
report generated by the #S0 command on the
system supervisor console display. The speed
options are as follows:
#RB300
: 300 bps
#RB2400 : 2400 bps
#RB9600 : 9600 bps
#RT0-99
Status Report Time
This command sets the time interval in hours at
which the status report generated by the #S0
command is displayed on thesystem supervisor
console display. The intervals are in hour increments
from 1 to 99 hours with #RT0 being the off condition.
$Muxl
Inactivity Timer
The inactivity timer allows the mux to drop DTR
which causes the modem to hang up when no
characters are received on any channel for the
specified time. The timer is enabled with the$Muxl
command where the xx is the desired inactivity time
in minutes (00-99 minutes). When a character is
received on a channel, the mux raises the DTR
signal allowing the modem to dial. When the xx is
00, the timer if off. The default for the inactivity timer
is off.
Chapter 5 - Commands
MODEM
FLUSH
RESPONSE
TIMER
TIME
INTERNAL 10ms
3
#RB120O : 1200 bps
#RB4800
: 4800 bps
#RB19200 : 19200bps
75