5 Install and tighten the 2 screws to fix the swing raster motor to the bracket.
6 Install the swing raster motor assembly on the correct location on the indoor
unit while guiding the rod inside the swing raster compartment.
7 Install the 2 screws to fix the swing raster motor assembly. Do NOT yet tighten
the screws.
d
e
a Swing raster motor cover
b Swing raster motor assembly
c Screw (swing raster motor assembly)
d Fan guard
e Swing raster motor rod
8 Connect the swing raster motor rod to the swing raster shaft using soft tools.
9 Tighten the 2 screws to properly fix the swing raster motor assembly.
10 Install the fan guard.
11 Install the swing raster motor cover.
12 Connect the drain hose to the indoor unit.
a Screw (drain hose)
b Drain hose
13 Install the drain hose fixation bracket. Install and tighten the screw.
14 Install the switch box, see
Is the problem solved?
Yes
c
b
a
c
b
a
4
"4.17 Plate
work" [
 144].
Action
No further actions required.