▪ A subset of the latest technical data is available on the regional 9 Configuration Daikin website (publicly accessible). To set a different address............▪ The full set of latest technical data is available on the Daikin Business Portal (authentication required). 10 Commissioning 10.1 Checklist before commissioning..........
▪ the mounting plate attached to the back of the indoor unit, ▪ the spare SSID sticker located on the front grille. 1× 1× 1× 2× 2× 2× 1× 1× 1× 2× 1× Installation manual Operation manual General safety precautions FTXTA30B2V1B(W)(B) Installation manual Daikin room air conditioner 3P482320-12U – 2021.03...
INFORMATION relative humidity of 80%, or when fresh air is inducted into the ▪ Daikin Industries Czech Republic s.r.o. declares that wall, then additional insulation is required (minimum 10 mm the radio equipment type inside of this unit is in thickness, polyethylene foam).
4 After completing wiring, refrigerant piping and drain piping, do NOT forget to seal the gap with putty. 2 Insert a wall embedded pipe into the hole. 3 Insert a wall cover into the wall pipe. FTXTA30B2V1B(W)(B) Installation manual Daikin room air conditioner 3P482320-12U – 2021.03...
The factory default is right-side piping. For left-side piping, joints directly connecting the piping to the indoor units. remove the piping from the right side and install it on the left side. Installation manual FTXTA30B2V1B(W)(B) Daikin room air conditioner 3P482320-12U – 2021.03...
H05RN-F (60245 IEC 57) 1 Connect refrigerant piping to the unit using flare connections. 2 Insulate the refrigerant piping, interconnection cable and drain hose on the indoor unit as follows: FTXTA30B2V1B(W)(B) Installation manual Daikin room air conditioner 3P482320-12U – 2021.03...
Refrigerant piping Indoor unit fixing screw M4×12L (accessory) 9 Pull the wires to make sure that they are securely attached, Bottom frame then retain the wires with the wire retainer. Installation manual FTXTA30B2V1B(W)(B) Daikin room air conditioner 3P482320-12U – 2021.03...
4 Secure the indoor unit to the mounting plate using 2 indoor unit fixing screws M4×12L (accessory). Configuration To set a different address In case 2 indoor units are installed in 1 room, different addresses for 2 user interfaces can be set. FTXTA30B2V1B(W)(B) Installation manual Daikin room air conditioner 3P482320-12U – 2021.03...
The fuses or locally installed protection devices are Daikin website (publicly accessible). installed according to this document, and have NOT been ▪ The full set of latest technical data is available on the Daikin bypassed. Business Portal (authentication required). The power supply voltage matches the voltage on the identification label of the unit.
Page 11
Compressor motor Fan motor Drain pump motor Swing motor MR*, MRCW*, MRM*, MRN* Magnetic relay Neutral n=*, N=* Number of passes through ferrite core Pulse-amplitude modulation PCB* Printed circuit board FTXTA30B2V1B(W)(B) Installation manual Daikin room air conditioner 3P482320-12U – 2021.03...
Page 12