Daikin RXTA30B2V1B Service Manual page 189

R32 optimized heating 4 split
Hide thumbs Also See for RXTA30B2V1B:
Table of Contents

Advertisement

RXTM-R+RXTP-R+ARXTP-R+RXTA-B+FTXTA30B2V1B(W)
(B)+FTXTM30+40R2V1B+FTXTP25+35M5V1B+ATXTP25+35M5V1B
R32 Optimized Heating 4 Split
ESIE21-12A – 2022.02
b
c
d
a Rod
b Link
c Screw (swing raster motor fixation)
d Swing raster motor
9 Remove the 2 screws that fix the swing raster motor to the bracket.
10 Remove the swing raster motor.
11 Disconnect the wiring harness from the swing raster motor.
12 To install the swing raster motor, see
FTXTM40R
Prerequisite: Stop the unit operation via the user interface.
Prerequisite: Turn OFF the respective circuit breaker.
Prerequisite: Remove the required plate work, see
1 Remove the switch box, see
2 Put a small drain pan (or container) under the drain hose.
3 Remove the screw from the fixation bracket and pull the drain hose
downwards to remove it from the indoor unit.
a Screw (drain hose)
b Drain hose
4 Remove the swing raster motor cover.
c
a
"4.21.2 Repair
"4.17 Plate
work" [
b
a
4
Components
|
4
procedures" [
 186].
4
"4.17 Plate
work" [
 144].
4
 144].
Service manual
189