Daikin RXTA30B2V1B Service Manual page 187

R32 optimized heating 4 split
Hide thumbs Also See for RXTA30B2V1B:
Table of Contents

Advertisement

RXTM-R+RXTP-R+ARXTP-R+RXTA-B+FTXTA30B2V1B(W)
(B)+FTXTM30+40R2V1B+FTXTP25+35M5V1B+ATXTP25+35M5V1B
R32 Optimized Heating 4 Split
ESIE21-12A – 2022.02
a Swing raster motor cover
b Swing raster motor assembly
c Screw
3 Remove the 2 screws that fix the swing raster motor assembly to the indoor
unit.
4 Disconnect the swing raster shaft from the swing raster motor rod.
a
c
a Swing raster shaft
b Swing raster motor rod
c Swing raster motor assembly
5 Remove the swing raster motor assembly from the indoor unit.
6 Remove the 2 screws that fix the swing raster motor to the bracket.
7 Disconnect the rod from the swing raster motor and remove the motor. Keep
the rod and bracket for reuse.
8 To install the swing raster motor, see
FTXTM30R
Prerequisite: Stop the unit operation via the user interface.
Prerequisite: Turn OFF the respective circuit breaker.
Prerequisite: Remove the required plate work, see
1 Remove the switch box, see
2 Put a small drain pan (or container) under the drain hose.
b
c
a
b
"4.21.2 Repair
"4.17 Plate
work" [
4
Components
|
4
procedures" [
 186].
4
"4.17 Plate
work" [
 144].
4
 144].
Service manual
187