4
|
Components
To remove the swing flap motor wiring harness
To install the swing flap motor wiring harness
Service manual
178
Is the problem solved?
Yes
No
FTXTM40R
Prerequisite: Stop the unit operation via the user interface.
Prerequisite: Turn OFF the respective circuit breaker.
Prerequisite: Remove the required plate work, see
1 Remove the swing flap motor, see
INFORMATION
The swing flap motor wiring harness is also connected to the swing raster motor.
2 Put a small drain pan (or container) under the drain hose.
3 Remove the screw from the fixation bracket and pull the drain hose
downwards to remove it from the indoor unit.
c
a Screw (drain hose)
b Drain hose
c Swing raster motor cover
4 Remove the swing raster motor cover.
5 Disconnect the wiring harness from the swing raster motor.
6 Remove the swing flap motor wiring harness.
7 To install the swing flap motor wiring harness, see
4
procedures" [
 206].
FTXTM40R
1 Connect the wiring harness connector to the swing raster motor.
2 Install the swing raster motor cover.
Action
No further actions required.
Return to the troubleshooting of the
specific error and continue with the
next procedure.
"4.17 Plate
4
"Repair
procedures" [
b
a
RXTM-R+RXTP-R+ARXTP-R+RXTA-B+FTXTA30B2V1B(W)
(B)+FTXTM30+40R2V1B+FTXTP25+35M5V1B+ATXTP25+35M5V1B
4
work" [
 144].
 181].
"4.23.2  Repair
R32 Optimized Heating 4 Split