Daikin RXTA30B2V1B Service Manual page 121

R32 optimized heating 4 split
Hide thumbs Also See for RXTA30B2V1B:
Table of Contents

Advertisement

To install the intelligent eye sensor
To remove the intelligent eye sensor wiring harness
RXTM-R+RXTP-R+ARXTP-R+RXTA-B+FTXTA30B2V1B(W)
(B)+FTXTM30+40R2V1B+FTXTP25+35M5V1B+ATXTP25+35M5V1B
R32 Optimized Heating 4 Split
ESIE21-12A – 2022.02
a
a Control panel
b Intelligent eye sensor PCB
2 Disconnect the connector from the intelligent eye sensor PCB.
3 Carefully click the complete intelligent eye sensor PCB out of the indoor unit.
4 To
install
the
4
procedures" [
 120].
1 Click the intelligent eye sensor PCB on the indoor unit.
a
a Control panel
b Intelligent eye sensor PCB
2 Connect the harness to the intelligent eye sensor PCB.
3 Install the control panel on the indoor unit.
Is the problem solved?
Yes
No
Prerequisite: Stop the unit operation via the user interface.
Prerequisite: Turn OFF the respective circuit breaker.
Prerequisite: Remove the required plate work, see
b
intelligent
eye
sensor
b
Action
No further actions required.
Return to the troubleshooting of the
specific error and continue with the
next procedure.
4
Components
|
PCB,
see
"4.12.2  Repair
4
"4.17 Plate
work" [
 144].
Service manual