Daikin RXTA30B2V1B Service Manual page 130

R32 optimized heating 4 split
Hide thumbs Also See for RXTA30B2V1B:
Table of Contents

Advertisement

4
|
Components
To perform a diode module check
Service manual
130
INFORMATION
When measuring on the front of the main PCB, make sure to locally remove the
protective varnish with the test leads of the multi meter.
Is the measured rectifier voltage
correct?
Yes
No
1 First check the rectifier voltage of the main PCB, see
4
procedures" [
 126].
INFORMATION
If the rectifier voltage is OK, the diode module is OK. If rectifier voltage is NOT OK,
proceed as described in the rectifier voltage check procedure.
Below procedure describes how to check the diode module itself.
Prerequisite: Stop the unit operation via the user interface.
2 Turn OFF the respective circuit breaker.
DANGER: RISK OF ELECTROCUTION
Wait for at least 10 minutes after the circuit breaker has been turned OFF, to be sure
the rectifier voltage is below 10 V DC before proceeding.
3 Check the diode module in reference with the image and the table below.
a b c d
a V DC out (+)
b V AC in
c V AC in
d V DC out (–)
INFORMATION
When measuring on the front of the main PCB, make sure to locally remove the
protective varnish with the test leads of the multi meter.
VDC
Com
d
b
b
a
d
c
Action
Perform a check of the power modules,
see
"4.14.1 Checking
procedures" [
Replace the main PCB, see
"4.14.2 Repair
Ref
VDC
0.51~0.52 V
b
0.51~0.52 V
a
0.51~0.52 V
c
RXTM-R+RXTP-R+ARXTP-R+RXTA-B+FTXTA30B2V1B(W)
(B)+FTXTM30+40R2V1B+FTXTP25+35M5V1B+ATXTP25+35M5V1B
4
 126].
4
procedures" [
 132].
"4.14.1  Checking
Com
Ref
d
O.L
b
O.L
d
O.L
R32 Optimized Heating 4 Split