4
|
Components
To install the intelligent thermal sensor
Service manual
124
1 Carefully click the complete intelligent thermal sensor assembly out of the
indoor unit.
a Intelligent thermal sensor assembly
2 Disconnect the wiring harness from the intelligent thermal sensor PCB.
3 Click the intelligent thermal sensor PCB out of the bracket.
4 To
install
the
4
procedures" [
 123].
1 Connect the wiring harness to the connector of the intelligent thermal sensor
PCB.
2 Install the intelligent thermal sensor PCB in the bracket.
3 Route the wiring harness along the harness retainers on the intelligent
thermal sensor assembly.
4 Click the intelligent thermal sensor assembly on the indoor unit.
a Intelligent thermal sensor assembly
Is the problem solved?
Yes
No
a
intelligent
thermal
a
Action
No further actions required.
Return to the troubleshooting of the
specific error and continue with the
next procedure.
RXTM-R+RXTP-R+ARXTP-R+RXTA-B+FTXTA30B2V1B(W)
(B)+FTXTM30+40R2V1B+FTXTP25+35M5V1B+ATXTP25+35M5V1B
sensor,
see
"4.13.2  Repair
R32 Optimized Heating 4 Split