Daikin RXTA30B2V1B Service Manual page 162

R32 optimized heating 4 split
Hide thumbs Also See for RXTA30B2V1B:
Table of Contents

Advertisement

4
|
Components
To re-install the front panel
To install the switch box
Service manual
162
4 Install the air filter, mount the front panel and close it.
FTXTP-M and ATXTP-M units
1 Install the front grille and firmly engage the 3 upper hooks.
2 Install 2 screws (class 20~35) or 3 screws (class 50~71) back on the front grille.
3 Install 2 screws back on the front grille.
4 Install the air filter and then mount the front panel.
FTXTA-B units
1 Attach the front panel.
2 Align the shaft on right side with the shaft slot and insert it all the way in.
3 Push lightly the front panel to the right side, align the shaft on the left side
with slot and insert it all the way in.
4 Close the locks on both sides.
FTXTM-R, FTXTP-M and ATXTP-M units
1 Attach the front panel. Align the shafts with the slots and push them all the
way in.
2 Close the front panel, see
FTXTA-B units
1 install the switch box in the correct location on the indoor unit.
b
a
a Grouding wire cover screw
b Grounding wire screw
c Heat exchanger thermistor
d Indoor unit PCB
e Switch box screw
f Switch box
2 Route the connectors of the indoor unit fan motor and front wiring inside the
switch box and connect them to the indoor unit PCB.
3 Install and tighten the screw to secure the switch box.
4 Install the heat exchanger thermistor in its holder.
4
"4.17 Plate
work" [
 144].
c
e
RXTM-R+RXTP-R+ARXTP-R+RXTA-B+FTXTA30B2V1B(W)
(B)+FTXTM30+40R2V1B+FTXTP25+35M5V1B+ATXTP25+35M5V1B
f
d
R32 Optimized Heating 4 Split
ESIE21-12A – 2022.02

Hide quick links:

Advertisement

Table of Contents
loading