Daikin RXTA30B2V1B Service Manual page 192

R32 optimized heating 4 split
Hide thumbs Also See for RXTA30B2V1B:
Table of Contents

Advertisement

4
|
Components
Service manual
192
FTXTM30R
1 Connect the wiring harness to the swing raster motor.
2 Install the swing raster motor on the correct location on the bracket.
b
c
d
a Rod
b Link
c Screw (swing raster motor fixation)
d Swing raster motor
3 Install and tighten the 2 screws to fix the swing raster motor to the bracket.
4 Guide the rod and link inside the bracket to the correct location.
5 Connect the rod and link to the swing raster motor.
6 Install the swing raster motor assembly on the correct location on the indoor
unit while guiding the rod inside the swing raster compartment.
7 Install the 2 screws to fix the swing raster motor assembly. Do NOT yet tighten
the screws.
c
d
a Screw (swing raster motor assembly)
b Swing raster motor assembly
c Fan guard
d Swing raster motor rod
8 Connect the swing raster motor rod to the swing raster shaft using soft tools.
9 Tighten the 2 screws to properly fix the swing raster motor assembly.
10 Install the fan guard.
c
a
a
b
RXTM-R+RXTP-R+ARXTP-R+RXTA-B+FTXTA30B2V1B(W)
(B)+FTXTM30+40R2V1B+FTXTP25+35M5V1B+ATXTP25+35M5V1B
a
R32 Optimized Heating 4 Split
ESIE21-12A – 2022.02

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents