Software Configuration (Before Serial Numbers Gs3005-75000, Gs3205-75000 And Gs4605-75000) - Terex Genie GS-1530 Service Manual

Hide thumbs Also See for Genie GS-1530:
Table of Contents

Advertisement

June 2009
REV D
1-3
Software Configuration
(before serial numbers GS3005-75000,
GS3205-75000 and GS4605-75000)
The ECM (Electronic Control Module) contains
programming for all configurations of the Genie
GS-30, GS-32 and GS-46. The machine can be
adjusted to a different configuration by changing
the toggle settings on the DIP switch. The DIP
switch is located on the circuit board inside the
platform control box.
DIP switches have two positions - on and off.
When reading the DIP switch code in the DIP
Switch Code Chart , the on and the off are
represented by the numbers 1 (on) and 0 (off).
How to Determine the
DIP Switch Configuration
1 Remove the platform controls from the platform.
2 Place the platform controls close to the
diagnostic display on the power unit side of the
machine.
3 Turn the key switch to platform control and pull
out the red Emergency Stop button to the on
position at both the ground and platform
controls.
4 Press and hold the lift function enable button
OR press the lift function select button.
5 Slowly move the joystick in the direction
indicated by the blue arrow.
Result: The DIP switch configuration will appear
in the diagnostic display.
Part No. 96316
Machine Option Definitions
Motion Beacon: The motion beacon option
flashes only when operating a function.
Motion Alarm: The motion alarm will sound
when operating any function.
Lift/Drive Cut Out: This cuts out lift and drive
functions when the machine exceeds the
rating on the serial plate. Configured on all
machines.
Platform Overload: This cuts out all functions
when the pressure sensor is overloaded. The
additional weight must be removed from the
platform before any function can be resumed.
Required for CE models.
Descent Delay: This option halts descent at
approximately 7 feet / 2.1 m. All controls must
be released for 4 to 6 seconds before descent
is re-enabled. Required for CE models.
Battery Drain Alarm: When the machine is
turned on and no function is activated for 10
minutes, the alarm will sound once every 3
seconds. This option can be activated by
moving DIP switch 7 to
position 1.
When this option is configured, the flashing dot
in the diagnostic display window will remain
continuously illuminated when the lift mode is
selected and activated.