Mitsubishi Electric MELSEC iQ-R Series User Manual page 233

System recorder
Hide thumbs Also See for MELSEC iQ-R Series:
Table of Contents

Advertisement

■Project data saving completion
Whether saving project data is completed is stored.
Each value is stored at each timing as follows:
• Not completed (0): Preparation for project data saving starts.
• Completed (1): Saving project data is completed.
■Project data saving result
The saving result of project data is stored.
Each value is stored at each timing as follows:
• No failure (0): Preparation for project data saving starts.
• Failure (1): Saving project data fails.
■Project data saving completion code
The saving completion code for project data is stored. If the saving fails, an event code is stored.
Each value is stored at each timing as follows:
• No failure (0): Preparation for project data saving starts.
• Event code: Saving project data fails.
6 RECORDER MODULE (DETAILED SPECIFICATIONS)
231
6.4 Buffer Memory
6