"Specify the Device Range" screen

The range of devices to be sampled can be specified individually.
Window
Click the [Setting] button next to "Specify the Device Range" under "Device/Label Sampling Target Setting."
Displayed items
Item
Specify the Device
*1
Range
Sampling Size (Specify the Device Range)
*1 Up to 65536 rows can be set.
*2 Displayed in red for a local device when any of the following conditions is satisfied.
No program file is registered in the corresponding execution program number.
The program file of the corresponding execution program number does not exist in the navigation window.
A program file registered in the corresponding execution program number is unconverted.
A program file registered in the corresponding execution program number is a standard program when "Safety Cycle Time" is selected
for "Sampling Method."
*3 Cannot be set in any of the following cases:
The cell in "Device/Local Device" is blank.
For a local device, no program file is registered in the corresponding execution program number.
For a local device, a program file registered in the corresponding execution program number is a standard program when "Safety Cycle
Time" is selected for "Sampling Method."
*4 Displayed in red in any of the following cases:
A standard device is specified when "Safety Cycle Time" is selected for "Sampling Method."
The device range is not set in the CPU parameter.
The specified device is out of the range set in the CPU parameter.
For a local device, a safety device is specified when a program file registered in the corresponding execution program number is a
standard program.
For a local device, a standard device is specified when a program file registered in the corresponding execution program number is a
3 RECORDING SETTING
132
3.3 Device/Label Sampling Setting
Description
Specify a device.
The following two types of setting methods are available and can be switched by right-clicking in the
screen and selecting [Setting Method]  [Start/End] or [Points/Start].
• Start/End: To set the start and end devices to automatically acquire the number of points.
• Points/Start: To set the start device and the number of points to automatically acquire the end
device.
When entering a device corresponding to the current value, coil, or contact of a timer or counter, it is
replaced with its base device symbol.
Device/Local Device
Select the type of a device (local device or global device).
For a local device, also select a program to which the device belongs.
A program name displayed in this item depends on the execution program number.
Start Device
Specify the start of devices to be sampled.
End Device
Specify the end of devices to be sampled.
Points (Decimal)
Specify the number of device points to be sampled.
Sampling Target
The range of devices to be sampled is displayed based on the sampling unit.
For the sampling unit of each device, refer to the following:
Page 31 Devices and labels that can be sampled
Size [Word]
The size of a device to be sampled is displayed.
The total size of sampling target devices specified by using 'specify the device range' is
displayed.
*3*4
*4*5
*8*9
*2
*6
*7