Event
Event type
Event
code
classificatio
n
2A052
Operation
Warning
2A053
Operation
Warning
2A054
Operation
Warning
2A055
Operation
Warning
2A056
Operation
Warning
2A057
Operation
Warning
Overview
Project Data Saving Failure
Project Data Saving Failure
Project Data Saving Failure
Project Data Saving Failure
Project Data Saving Failure
Project Data Saving Failure
Cause
Failed to save the project data because connecting
to the file server (the saving path set in the recording
setting) failed due to any one of the following causes.
• The saving path set in the saving path setting does
not exist.
• The user name/password set in the saving path
setting is incorrect.
• The host name/IP address set in the saving path
setting is incorrect.
• Any item in the DNS setting (the basic settings of
the module parameter) is incorrect.
• The file server is not connected to the network.
• The saving path set in the saving path setting or
files and folders under them are set Read-only or
Encrypt attributes.
Failed to save the project data to the file server (the
saving path set in the recording setting) due to any
one of the following causes.
• The free space in the file server is insufficient.
• The user set in the saving path setting does not
have write authority to the saving path.
• An error has been detected at the time of access to
the save destination folder due to network
disconnection.
• An error has been detected since several modules
and applications were accessing the saving
destination folder simultaneously.
• The saving path set in the saving path setting or
files and folders under them are set Read-only or
Encrypt attributes.
Since the CPU module is not supported by the
project data saving function, the project data was not
saved.
Since the project data in the CPU module was
changed while the project data was being saved, the
project data was not saved.
Failed to save the project data because acquiring the
project data from the CPU module failed due to any
one of the following causes.
• The file password (read) is set.
• Several modules and applications are accessing
the CPU module.
Since initializing the SD memory card was requested,
the project data was not saved.