Mitsubishi Electric MELSEC iQ-R Series User Manual page 230

System recorder
Hide thumbs Also See for MELSEC iQ-R Series:
Table of Contents

Advertisement

Recording operation specification area (Un\G4000 to 4799)
File saving triggers for recording, the recording buffer batch saving mode, and data values added to save folder names can be
checked.
Buffer memory name
Recording operation
specification 1
Recording operation specification 2 to 4
*1 '0' is stored when powering ON or resetting a CPU module.
■Recording buffer batch saving mode (Un\G4001)
Use this to specify the recording buffer batch saving mode. (Page 62 Recording buffer batch saving mode)
A value when a file saving trigger is satisfied will be valid.
'0' (not use the batch saving mode) is stored at either of the following timings:
• A CPU module is powered ON or reset.
• The operating status switches to 'operating' after writing a recording setting.
■Folder name additional data 1 to 4 (Un\G4002 to 4003, Un\G4004 to 4005, Un\G4009 to 4016,
Un\G4025 to 4032)
Use these to specify data added to a recording file save folder name. (Page 49 Recording file)
When setting "DATA1," "DATA2," "DATA3," or "DATA4" as additional information for a folder name, a value in the buffer
memory is added to the folder name.
A value when a file saving trigger is satisfied will be valid.
A value is cleared to the initial value (0) at either of the following timings:
• A CPU module is powered ON or reset.
• The operating status switches to 'operating' after writing a recording setting.
■File saving trigger (Un\G4007)
Use this for file saving triggers.
It can be used in bit units.
A condition number is added to each bit as follows:
Condition number
Recording setting No.1: Un\G4007
Recording setting No.2: Un\G4107
Recording setting No.3: Un\G4207
Recording setting No.4: Un\G4307
A value is cleared to the initial value (OFF) at either of the following timings:
• A module is started.
• The operating status switches to 'operating' after writing a recording setting.
6 RECORDER MODULE (DETAILED SPECIFICATIONS)
228
6.4 Buffer Memory
Address
Recording buffer batch
Un\G4001
saving mode
Folder name additional data
Un\G4002 to 4003
1
Folder name additional data
Un\G4004 to 4005
2
File saving trigger
Un\G4007
Timeout detection of file
Un\G4008
*1
saving trigger
Folder name additional data
Un\G4009 to 4016
3
Folder name additional data
Un\G4025 to 4032
4
Un\G4100 to 4399
1
2
3
4
5
b0
b1
b2
b3
b4
b0
b1
b2
b3
b4
b0
b1
b2
b3
b4
b0
b1
b2
b3
b4
Description
Use this to specify the recording buffer batch saving mode.
When enabling this mode, '1' (ON) is stored.
0: Not use the batch saving mode (OFF)
1: Use the batch saving mode (ON)
Data 1 added to a recording file save folder name.
Use this when specifying "DATA1" as additional information for a recording
file save folder name.
Data 2 added to a recording file save folder name.
Use this when specifying "DATA2" as additional information for a recording
file save folder name.
Use this for file saving triggers.
Use this to specify whether to enable or disable timeout detection.
0: Enabled
1: Disabled
Data 3 added to a recording file save folder name.
Use this when specifying "DATA3" as additional information for a recording
file save folder name.
Data 4 added to a recording file save folder name.
Use this when specifying "DATA4" as additional information for a recording
file save folder name.
Details are the same as recording operation specification 1.
6
7
8
9
10 11 12 13 14 15 16
b5
b6
b7
b8
b9
b10
b11
b12
b5
b6
b7
b8
b9
b10
b11
b12
b5
b6
b7
b8
b9
b10
b11
b12
b5
b6
b7
b8
b9
b10
b11
b12
b13
b14
b15
b13
b14
b15
b13
b14
b15
b13
b14
b15