Chapter 2. Installation
2-14
Termination of the supplementary equipment
grounding conductor is permitted to be made to
building steel, to a metal electrical raceway system,
or to any grounded item that is permanently and
reliably connected to the electrical service equipment
ground.
The supplemental grounding conductor shall be
connected to the equipment using a number 8 ring
terminal.
The terminal should be fastened to the grounding
lug provided on the rear panel of the equipment.
The ring terminal should be installed using the
appropriate crimping tool (AMP P/N 59250 T-EAD
Crimping Tool or equivalent).
TSU 610 User Manual
61200610L2-1