Connecting to the CX-Programmer Version 2.1 or Lower

3-8-2 How to Connect with CX-Programmer

AUDIN - 8, avenue de la malle - 51370 Saint Brice Courcelles - Tel : 03.26.04.20.21 - Fax : 03.26.04.28.20 - Web : http: www.audin.fr - Email : info@audin.fr
Disconnect
·
Guide to Connect
·
Close
·
Note Correct the Node address of FinsGateway Communications Unit only if it
overlaps with the node address of the Network Communications Unit when
connecting to the CX-Simulator.
This section explains how to connect the CX-Simulator with the CX-
Programmer.
1. Start the CX-Simulator and select a PLC data folder needed for debugging
1,2,3...
application programs. The windows for [Work CX-Simulator], [CX-
Simulator Debug Console], and [System Status Setting] are displayed.
2. Press the [Connect] button in the [Work CX-Simulator] window. The FINS
Address to be set to the CX-Programmer will be displayed in the Guide to
Connect.
Exit the FinsGateway Communications Unit
started when connecting to the CX-Simulator
and return to the status before the startup.
Disconnecting the CX-Simulator will bring the
CX-Simulator to the following.
The FinsGateway Communications Unit
·
stops.
Restore the routing table of FinsGateway to
·
the original status.
The Serial Communications Server stops.
·
The mode will be in PROGRAM if the Lad-
·
der Engine is running.
Display the settings for connecting with the
CX-Simulator.
Exit the window with the present settings.
FINS address to be
Section 3-8
set to the CX-
Programmer
69