Error Processing

10-1 Error Processing

10-1-1 CX-Programmer

10-1-2 Debugger and Ladder Engine

Symptoms
A communications error has oc-
curred with CX-Simulator Ladder
Engine.
An error occurred while initializ-
ing Debugger startup. Start De-
bugger again.
Cannot open the communica-
tions with current settings. The
network No. used in the routing
table of FinsGateway is used in
the relay node table of CX-
Simulator Ladder Engine.
Failed to start Block Run of the
selected cyclic task.
Failed to create a PLC data
folder.
Failed to gain the access rights
of CX-Simulator Ladder Engine.
Failed to read the PLC data file.
Failed to read the routing table
for FinsGateway. Check a routing
table for it.
Failed to save PLC data file.
Failed to start CX-Simulator Lad-
der Engine.
Failed to start Data Replay Tool.
232
AUDIN - 8, avenue de la malle - 51370 Saint Brice Courcelles - Tel : 03.26.04.20.21 - Fax : 03.26.04.28.20 - Web : http: www.audin.fr - Email : info@audin.fr
For the details of errors and remedies when operating the CX-Simulator from
the CX-Programmer, refer to the CX-Programmer User manual.
If an error occurs while operating the CX-Simulator, the error contents will be
displayed in the dialog box. Remove the error causes referring to the reme-
dies.
Note For errors relating to the execution of ladder programs, refer to the CX-
Programmer User Manual or CS/CJ Series Operation Manual and Program-
ming Manual.
Causes
Wrong communi-
cations environ-
ment.
Wrong execution
environment.
Setting of the
routing table is
wrong.
Low hard disk
space or no ac-
cess right.
Another applica-
tion program is
writing to the UM.
The set file is bro-
ken.
Wrong setting of
the routing table.
Low hard disk
space or no ac-
cess right.
Wrong execution
environment.
Wrong execution
environment.
Remedies
1. [Disconnect] and [Connect] and then try again.
2. Exit executing application programs excluding the
CX-Simulator and try again.
3. Uninstall and then reinstall the CX-Simulator.
1. Exit executing application programs excluding the
CX-Simulator and try again.
2. Uninstall and then reinstall the CX-Simulator.
Reset the routing table of the Ladder Engine using
the CX-Net so that it does not overlap with the net-
work No. used by FinsGateway.
The Block Run of a task can be executed only when
stopping (Program mode).
Check if the folder is read-only or the user is author-
ized to write.
After the application program being writing is com-
pleted, try again.
Reset the set file in the setting wizard.
Reset the routing table using the CX-Net.
Check if the hard disk has enough space and the
user is authorized to write.
1. Exit executing application programs excluding the
CX-Simulator and try again.
2. Uninstall and then reinstall the CX-Simulator.
1. Exit executing application programs excluding the
CX-Simulator and try again.
2. Uninstall and then reinstall the CX-Simulator.
Section 10-1