Running by Virtual External Inputs
Example for Operation Tim-
ing of the I/O Condition Ex-
pressions
How to Replay using the I/O
Condition Tool
AUDIN - 8, avenue de la malle - 51370 Saint Brice Courcelles - Tel : 03.26.04.20.21 - Fax : 03.26.04.28.20 - Web : http: www.audin.fr - Email : info@audin.fr
The following example shows the timing from when the I/O Condition expres-
sions hold to when the values registered in the output expressions are set, if
the delay time is 200 ms.
IO 0.0
Conditions
hold.
IO 0.1
This section explains how to perform virtual external input using the I/O Con-
dition Tool.
1. Select [IO Condition] in the [CX-Simulator Debug Console] | [Replay]
1,2,3...
menu to display the [Run] window of the I/O Condition Tool.
2. Input "IO condition file" to the execution file. Browsing files using the
[Browse] button or [Open] in the [File] menu is also possible.
3. Check the target FINS address. Usually there is no need to change it be-
cause the FINS address for the Ladder Engine is set in default.
4. Check whether or not Synchronous process is specified. Multiple Syn-
chronous processes can not be performed at the same time. When an-
other Synchronous process is needed, remove the check mark for the
Synchronous process.
5. After checking the settings, click the [Start] button.
200 ms
ON
OFF
ON
OFF
Set output expressions.
Section 8-4
Condition expression: IO0.0=ON
Delay time: 200ms
Output expression: IO0.1=ON
177