Omron CS Series Operator's Manual page 226

Cx-simulator
Hide thumbs Also See for CS Series:
Table of Contents

Advertisement

I/O Memory Allocation
Address
Words
Bits
A360 to
A36001
A391
to
A39115
A385
A38506
A38507
A392
A39204
A39205
A39206
A39207
AUDIN - 8, avenue de la malle - 51370 Saint Brice Courcelles - Tel : 03.26.04.20.21 - Fax : 03.26.04.28.20 - Web : http: www.audin.fr - Email : info@audin.fr
Name
Executed
The flag corresponding to the
FAL Num-
specified FAL number will be
ber Flags
turned ON when FAL(006) is
executed. Bits A36001 to A39115
correspond to FAL numbers 001
to 511.
The flag will be turned OFF when
the error is cleared.
File Deleted
The system deleted the remain-
Flags
der of an EM file memory file that
was being updated when a power
interruption occurred.
The system deleted the remain-
der of a Memory Card file that
was being updated when a power
interruption occurred.
RS-232C
ON when an error has occurred
Port Error
at the RS-232C port. (Not valid in
Flag
peripheral bus mode or NT Link
mode.)
RS-232C
ON when the RS-232C port is
Port Send
able to send data in no-protocol
Ready Flag
mode.
(No- proto-
col mode)
RS-232C
ON when the RS-232C port has
Port Re-
completed the reception in no-
ception
protocol mode.
Completed
When the number of bytes was
·
Flag
specified: ON when the specified
(No-
number of bytes is received.
protocol-
When the end code was speci-
·
mode)
fied: ON when the end code is
received or 256 bytes are re-
ceived.
RS-232C
ON when a data overflow oc-
Port Re-
curred during reception through
ception
the RS-232C port in no-protocol
Overflow
mode.
Flag
When the number of bytes was
·
(No-
specified: ON when more data is
protocol
received after the reception was
mode)
completed but before RXD(235)
was executed.
When the end code was speci-
·
fied: ON when more data is re-
ceived after the end code was
received but before RXD(235)
was executed. ON when 257
bytes are received before the end
code.
CS/CJ-series PLC
Function
1: That FAL
was exe-
cuted
0: That FAL
wasn't exe-
cuted
1: File de-
leted
0: No files
deleted
1: File de-
leted
0: No files
deleted
1: Error
0: No error
1: Able-to-
send
0: Unable-
to-send
1: Recep-
tion com-
pleted
0: Recep-
tion not
completed
1: Overflow
0: No over-
flow
Section 9-3
CX-Simulator
Settings
Function
Same as
CS/CJ-series
PLC.
Not used.
Not used.
Same as
CS/CJ-series
PLC.
Same as
CS/CJ-series
PLC.
Same as
CS/CJ-series
PLC.
Same as
CS/CJ-series
PLC.
Settings
211

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents