I/O Memory Allocation
Address
Words
Bits
A295
A29508
A29509
AUDIN - 8, avenue de la malle - 51370 Saint Brice Courcelles - Tel : 03.26.04.20.21 - Fax : 03.26.04.28.20 - Web : http: www.audin.fr - Email : info@audin.fr
Name
Instruction
This flag and the Error Flag (ER)
Processing
will be turned ON when an in-
Error Flag
struction processing error has
occurred and the PLC Setup has
been set to stop operation for an
instruction error. CPU Unit op-
eration will stop and the
ERR/ALM indicator will light
when this flag goes ON.
(The task number where the
error occurred will be stored in
A294 and the program address
will be stored in A298 and A299.)
Indirect
This flag and the Access Error
DM/EM
Flag (AER) will be turned ON
BCD Error
when an indirect DM/EM BCD
Flag
error has occurred and the PLC
Setup has been set to stop op-
eration an indirect DM/EM BCD
error. (This error occurs when
the content of an indirectly ad-
dressed DM or EM word is not
BCD although BCD mode has
been selected.) CPU Unit opera-
tion will stop and the ERR/ ALM
indicator will light when this flag
goes ON.
(The task number where the
error occurred will be stored in
A294 and the program address
will be stored in A298 and A299.)
CS/CJ-series PLC
Function
1: Error
Flag
ON
0: Error
Flag
OFF
1: Not BCD
0: Normal
Section 9-3
CX-Simulator
Settings
Function
Same as
CS/CJ-series
PLC.
Same as
CS/CJ-series
PLC.
Settings
205