Mitsubishi MELSEC QS Series Programming Manual page 82

Hide thumbs Also See for MELSEC QS Series:
Table of Contents

Advertisement

RST
Program Example
(1) The following program sets the value of the data register to 0.
[Ladder Mode]
(2) The following program resets the 100 ms retentive timer and counter.
[Ladder Mode]
5-30
5.3 Output Instruction
5.3.6 Resetting devices (except for annunciators) (RST)
Stores the values of X10 to X1F in D8 when
X0 is turned ON.
Sets the value of D8 to 0 when
X5 is turned ON.
When T225 is set as retentive timer, it is turned ON
when X4 ON time reaches 30 min.
Counts the number of times T225 was turned ON.
Resets the coil, contact and present value of T225
when the contact of T225 is turned ON.
Y55 is turned ON at the count up of C23.
Resets C23 when X5 is turned ON.