OUT C
Program Example
(1) The following program turns Y30 ON after X0 has gone ON 10 times, and resets the counter
when X1 goes ON.
[Ladder Mode]
(2) The following program sets the value for C10 at 10 when X0 goes ON, and at 20 when X1
goes ON.
[Ladder Mode]
5.3 Output Instruction
5-24
5.3.3 Counters (OUT C)
Stores 10 in D0 when X0 is turned ON.
Stores 20 in D0 when X1 is turned ON.
C10 counts data stored in D0 as the
set value.
Y30 is turned ON at the count up of C10.