5)
Devices which can be used by the instruction in question are indicated with circle.
The types of devices that can be used are as indicated below:
Internal Devices
(System, User)
Device Type
Bit
Word
X, Y, M
T, ST, C, *2
Applicable
SM, F,
D, W, SD,
devices *1
B, SB,
SW
*1: Refer to the manual below for the description for the individual devices.
• QSCPU User's Manual (Function Explanation, Program Fundamentals)
*2: When T, ST and C are used for other than the instructions below, only word data can be used.
(Bit data cannot be used.)
[Instructions that can be used with bit data]
LD, LDI, AND, ANI, OR, ORI, LDP, LDF, ANDP, ANDF, ORP, ORF, OUT, RST
*3: Devices which can be set are described in the "Constant" and the "Others" columns.
6)
Indicates the function of the instruction.
7)
Indicates conditions under which error is returned, and error number.
8)
Indicates simple program examples.
Also indicates the types of individual devices used when the program is executed.
Constant *3
Others *3
K, H
N, V
8)
4