Number
Name
Meaning
I/O module
I/O module
SD61
verify error
verify error
number
module number
Annunciator
Annunciator
SD62
number
number
Number of
Number of
SD63
annunciators
annunciators
SD64
SD65
SD66
SD67
SD68
SD69
SD70
Table of
SD71
Annunciator
detected
detection
SD72
annunciator
number
numbers
SD73
SD74
SD75
SD76
SD77
SD78
SD79
Cause of
SD81
Cause of error
error
TableApp.3.2 Special register
Explanation
• The lowest I/O number of the module where the I/O module
verification number took place.
• The first annunciator number (F number) to be detected is
stored here.
• Stores the number of annunciators searched.
• When F goes ON due to
OUT F
or
which go progressively ON from SD64 through SD79 are
registered.
• The F numbers turned OFF by
RST F
SD64 - SD79, and the F numbers stored after the deleted F
numbers are shifted to the preceding registers.
After 16 annunciators have been detected, detection of the
17th will not be stored from SD64 through SD79.
SET
SET
SET
RST
SET
SET
SET
SET
SET
F50
F25
F99
F25
F15
F70
F65
F38
F110
SD62 0 50 50 50 50 50 50 50 50 50 50 50 99 (Number
SD63 0
1
2
3
2
3
4
5
6
SD64
0 50 50 50 50 50 50 50 50 50 50 50 99
SD65
0
0 25 25 99 99 99 99 99 99 99 99 15
SD66
0
0
0 99 0 15 15 15 15 15 15 15 70
SD67
0
0
0
0
0
0 70 70 70 70 70 70 65
0 65 65 65 65 65 38
SD68
0
0
0
0
0
0
SD69
0
0
0
0
0
0
0
0 38 38 38 38 110
0 110 110 110 151
SD70
0
0
0
0
0
0
0
0
SD71
0
0
0
0
0
0
0
0
0
SD72
0
0
0
0
0
0
0
0
0
SD73
0
0
0
0
0
0
0
0
0
SD74
0
0
0
0
0
0
0
0
0
SD75
0
0
0
0
0
0
0
0
0
SD76
0
0
0
0
0
0
0
0
0
SD77
0
0
0
0
0
0
0
0
0
SD78
0
0
0
0
0
0
0
0
0
SD79
0
0
0
0
0
0
0
0
0
• When a continuation error occurs, the corresponding bits are
all set to ON.
• Canceling the error, starting up the safety PLC power or
canceling the safety CPU module reset after eliminating the
cause of the error makes the bits go OFF.
Bit No.
Name of the cause
0
Instantaneous power failure
1
Battery low
2
Standard ROM write count excess
3
TEST MODE continuous RUN tolerance timeout
4
Scan timeout
5
Annunciator ON
6
Safety remote station detection error
7
Safety remote station product information mismatch
8
Initial monitoring timeout error
Safety monitoring timeout error
Error monitoring timeout error
9
Safety remote station data split error
Safety remote command error
Safety remote station link ID error
Safety remote station running number error
Safety remote station reception data error
10 to 15
Empty (fixed to 0)
Appendix 3 SPECIAL REGISTER LIST
Set by
(When set)
S (Error)
S (Instruction
execution)
S (Instruction
execution)
SET F
, the F numbers
are deleted from
SET
SET
RST
F151
F210
F50
detected)
(Number of
7
8
9
8
S (Instruction
annunciators
detected)
execution)
0 151
151 210
(Number
detected)
0
0
210
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
S (Error)
Corresponding
CPU
QS
App-21

Advertisement

Table of Contents
loading

Table of Contents