Download Print this page

Ricoh F-40 Service Manual page 21

Advertisement

SUBJECT: Inverter Jam
3. ACTION IN THE FIELD (Temporary Solution)
Install the spacers. Line up the spacers with the arrows as shown.
Spacer : P/N A0458991 (Thickness = 0.5, Size = 10 X 80 mm)
Method of adhesion: Double sided tape
NOTE: This temporary solution has already been implemented from the November, '90
production run. This countermeasure will be applied until a permanent solution is
found.
4. PERMANENT SOLUTION
The open/shut guide plate has been made thicker by 0.7mm at the place where the
spacers were stuck on.
NOTE: This permanent solution has been implemented from the September '91
production run. (Refer to MB No. 24 issued on DEC. 15, '91)
Technical Bulletin
[ B ]
[ A ]
Open/Shut Guide Plate
SPACER (A0458991)
Place flat spacers [ A ] between the
open/shut guide plate and the magnet.
This will raise the open/shut guide
plate [ B ].
a + t
t = 0.7mm
No. RTB-005
DATE: Feb. 28, '91
PAGE: 4 of 4

Advertisement

loading