SUBJECT:
Platinum Corona Wire
--When to install the platinum corona wires-
The platinum corona wires do not have to be cleaned as often as the tungsten wires
(point 1). For this reason, the platinum corona wires are most suitable in cases where a
machine is installed in a relatively inaccessible location (far from a service center) and
service calls are difficult to make.
The platinum wires can be installed in the field on the following models:
Model
Main
F20
# 52199540
F21
F22
F30
# A0079540 # A0079542 # A0079541 Negative
F31
F33
F34
F40
Note 1
When installing the platinum corona wires, please take the following actions:
1. Clean the corona casings, end blocks, and new platinum wires with damp cloth.
2. Confirm VSG.
Note 2
# A0079540 can also be used as the F90 main corona wire.
Technical Bulletin
Transfer
# 52199540
# 52199540
PQC
PCC
Negative
charge.
Do not use.
charge.
Do not use.
No. RTB-006
DATE: Apr. 15, '91
PAGE: 2 of 2
Separation
Negative
Negative
charge.
charge.
Do not use.
Do not use.
Negative
Not used.
charge.
Do not use.
PTC