Mirus for H2 Classic GrainGage
Test Weight Sensor Settings
Setup Parameter
Test Weight Tare
Warning
Note: To edit other test weight settings see 4.3.1 Calibrate Test Weight on page 48
2. 3.6 Conf igure Moisture Sensors
On the Setup > H2 GrainGage > Sensors screen,
1. Tap Moisture.
Mirus opens the Moisture Sensor Setup screen where you can configure the moisture setting for the
GrainGage.
Moisture Sensor Settings
Setup Parameter
Moisture Tare
Warning
Note: To edit other moisture settings see 4.4.4 Chamber Calibration on page 54.
Mirus and H2 Classic GrainGage Setup
Default Value
Description
2 .02 lb/bu
A tare warning is generated above this threshold when the
2 .6 kg/hL
chamber is empty .
Default Value
Description
A tare warning is generated above this threshold when the
1%
chamber is empty .
.