Not Meeting Minimum Weight Threshold - Juniper HarvestMaster mirus H2 User Manual

Table of Contents

Advertisement

Mirus for H2 Classic GrainGage

8. 3. 2 Not Meeting Minimum Weight Threshold

The minimum weight threshold is the minimum amount of grain required for accurate moisture and test
weight data. By default, if the minimum weight threshold is not met, moisture and test weight data will be
recorded as zero.
To ensure the plots are yielding enough grain to measure accurate moisture and test weight,
Appendix B: Troubleshooting Mirus
1. Go to Setup > Info > Chamber Info.
• If the minimum weight threshold value is outside
2–6 lb., recalibrate the test weight for the chamber
calibration.
• If you are not harvesting enough grain to meet
the minimum weight threshold, install low yield
inserts and recalibrate the chamber. For more
information about low yield inserts, see 7 Appendix
A: Standard Grain Information on page 121.
• If installing low yield inserts doesn't work, there
is an option to override the minimum weight
threshold.
CAUTION: If the minimum weight threshold is
!
overridden, the moisture and test weight is not
guaranteed to be accurate.
To override the minimum weight threshold,
1. Go to Setup > System.
2. Change the Override Threshold option to Yes.
3. Tap Save.
Save