Mirus for H2 Classic GrainGage
Weight Diagnostics
Item
Weight
Load Cell 1
millivolts / Load
Cell 2 millivolts
Q
3.1.4 Moisture Diagnostics
H2 Classic GrainGage Diagnostics and Alerts
Description
Shows the weight of the contents in the weigh bucket . Depending on the
preferred units of measure, weight will be shown in pounds or kilograms .
To change the units of measure see 2.2.2 Set Preferred Units of Measure on
page 14 .
These readings are for the two load cells that measure plot weight . The
millivolt readings vary linearly with weight added . The empty weigh bucket
causes the load cells to read between 3 and 4 mV .
This multiplier corrects the weight measurement based on the slope and
motion of the weighing platform .
When Slope and Motion Compensation is disabled, Q is 1 .000 . When slope
and motion compensation is enabled, Q should be 1 .000 +/- .01 (depending
on the slope the combine is on or intensity of vibrations/movement) . If Q
value is off, see 4.1 Slope and Motion Calibration on page 43 .
On the Moisture Diagnostics screen, live values are shown
for the moisture sensor in the GrainGage.
Unlock the screen
to view additional
information.
36