ELECTRICAL CONNECTIONS (see Fig. 3)
WARNING: ELECTRICAL AND GROUNDING CONNECTIONS MUST COMPLY WITH THE NATIONAL
ELECTRICAL CODE AND/OR OTHER LOCAL CODES.
WARNING: DISCONNECT THE ELECTRICAL POWER SUPPLY AND PLACE A TAG AT THE
DISCONNECT SWITCH TO INDICATE THAT YOU ARE WORKING ON THE CIRCUIT.
The control box for field wire connection is located on the lower left side of the braising pan. A knockout
hole is provided for a 1" conduit connection.
1. Remove the control box cover plate. Mount suitable 1" conduit fitting in knockout opening.
2. Connect field wire to the terminal block as indicated on the wiring diagram. The wiring diagram is
located on the inside of the left door on closed base units and on the inside of the center door of
open base units. Wire must be of the type suitable for 75°C service, and of thickness as indicated
on marking next to junction box.
3. After making the connections, replace the control box cover plate.
4. The braising pan must be grounded by installing a ground lead, properly grounded, to the ground
lug located inside the junction box.
VOLTS
PHASE
208
240
208
240
480
These values are nominal ratings. Field wire connections must be capable of withstanding anticipated
surges.
CONTROL CIRCUIT POWER CONNECTION — All braising pans (see Fig's. 2 and 3)
WARNING: APPLIANCES EQUIPPED WITH A FLEXIBLE ELECTRIC SUPPLY CORD ARE PROVIDED
WITH A THREE-PRONG GROUNDING PLUG. IT IS IMPERATIVE THAT THIS PLUG B E CONNECTED
INTO A PROPERLY GROUNDED THREE-PRONG RECEPTACLE. IF THE RECEPTACLE IS NOT
THE PROPER GROUNDING TYPE, CONTACT AN ELECTRICIAN.
GROUNDING PRONG FROM THIS PLUG.
This connection is not required on braising pans equipped with the optional stepdown transformer.
Connect a 120 volt, 50/60 Hz, 1 phase supply to the pigtail leads in the junction box located on the rear
left of the braising pan. Use copper wire suitable for 5 amperes and 75°C temperature. A ground wire
must be connected to the ground lug in the junction box.
ELECTRICAL DATA CHART
E30C/O
K.W.
AMP
1
10.2
1
13.5
3
10.2
3
13.5
3
13.5
KW.
49
13.6
57
18.0
29
13.6
33
18.0
17
18.0
— 9 —