Electrical Connection; Water Connection - Vulcan-Hart PRECIPAN VPP28 Installation Manual

Intelligent braising pan
Hide thumbs Also See for PRECIPAN VPP28:
Table of Contents

Advertisement

Available languages

Available languages

3V-490072NI – 06/23
Caution: If you use the mobile stand accessory, installed the appliance with restraining means to guard against transmission of strain to the
connector.

ELECTRICAL CONNECTION

An approved means of electrical isolation that can be locked in a safe position must be fitted in the supply to this unit.
The installation must comply with current local and national standards. The unit must be earthed.
Different individual electrical units must be cross bonded (all metallic structures on the same circuit) using a connection point provided next
to the cable entry gland.
The instructions must provide recommendations regarding the characteristics and type of additional protective devices to be
installed, such as residual current device(s) (RCDs)
The electrical connection is at the front irrespective of the model. Fig. 5A-B-C
- Undo the two fixing screws holding the lower panelling
- Remove the panel.
- Pass the cable through the cable gland
- Connect the wires (respect Neutral and Earth).
- Tighten the cable gland.
- Refit the panel.
- Connect the cross bonding to the terminal provided. Fig. 5D
Allow for an approved isolation devise with a distance of at least 0.12 in between contacts.
The electric line must be eqquipped with overcurrent-protective appliances:
ELECTRIC APPLIANCE INSTALLED WITH MOBILE STAND:
The appliance shall be installed using flexible conduit.

WATER CONNECTION

The pipework must comply with the local regulations for connection to a drinking water supply.
Location, connections, and initial commissioning must only be undertaken by specialist concessionaires or approved personnel.
- Cold water max temperature: 73°F
- Hot water max temperature: 140°F
- Nature: Water filtered at 114 mesh
- Minimum / maximum pressure: 14.5 psi / 87 psi (1.5 bars, maxi: 6 bars).
- Water hardness: TH 6 à 10°fH (60 to 100 ppm) (3.5 to 5.8 grains/gal)
- Provide a local stop cock.
- Final connection at the rear via male thread G 3/4" + GHT adapter G3/4" Fig 3A
Attention: Fit an approved double check valve to comply with local water regulations.
F49570 (06-23)
Overcurrent-protective devices (A)
Models
208
VBPT10E
70
VBPT15E
125
Page 3
CONNECTION
240
480
60
40
90
60
VULCAN
A division of ITW Food Equipment Group LLC
P.O. Box 696
Louisville, KY 40201
Residual Current
Devices (RCDs):
Type AC
EN