Electrical Connections And Specifications - Vulcan-Hart VMCS Series Operation And Field Installation Manual

Heavy duty electric griddle top
Table of Contents

Advertisement

ELECTRICAL CONNECTIONS
Electrical
applicable portions of the National Electrical Code and/or other local electrical
codes.
Disconnect the electrical power to the griddle and follow lockout /
tagout procedures.
Since the griddle top is not fused, you must connect to a fused circuit equipped with a
suitable disconnecting means as required by local authorities.
Electrical Connections
1. Remove the small junction box cover plate on the back of the unit. This exposes the
VMCS clamshell griddle line leads.
2. Select a suitable knockout on the sides or bottom of the junction box.
3. Connect the griddle's line leads to the supply wires with factory supplied wire connectors as shown
in the applicable wiring diagrams.
4. Push the excess wire into the junction box and replace the cover plate. Never operate griddle
without cover in place.
Model No
VMCS-101
VMCS-102
VMCS-201
VMCS-202
and
grounding
ELECTRICAL SPECIFICATIONS
Description
FLAT
PLATE
GROOVED
PLATE
connections
Voltage
208V
240V
208V
240V
18
-
-
must
comply
Power
1 Phase Draw
3.6 KW
with
the
17.3 A
15.0 A
17.3 A
15.0 A

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vmcs-102Vmcs-101Vmcs-201Vmcs-202

Table of Contents