Fujitsu PRIMERGY TX200 S2 User Manual page 272

Hide thumbs Also See for PRIMERGY TX200 S2:
Table of Contents

Advertisement

Chapter 9 Operation and Maintenance
Operating system not found
Parity Check 1
Parity Check 2
Service Processor not properly installed
Unknown PCI Error
272
table: List of POST Errors
Message
Description
The OS to start cannot be found.
Check to see whether a floppy disk is unnecessarily inserted,
whether the cables of each device are connected correctly, or
whether the hard disk was successfully accessed during POST.
Also, start the BIOS Setup Utility and check the [Boot
Sequence] setting of the [Boot Option]. If the message still
appears, refer to "Contact Information" in "Start Guide", and
contact your maintenance engineer.
Power off the server and turn it back on. If the message still
appears, the keyboard must be replaced. Refer to "Contact
Information" in "Start Guide", and contact your maintenance
engineer.
The PCI is abnormal. Disregard this message if it is displayed
when pressing the NMI switch in MS-DOS. Otherwise, refer to
"Contact Information" in "Start Guide", and contact your
maintenance engineer.

Advertisement

Table of Contents
loading

Table of Contents