8.3.5 Adapter Properties

Detailed configuration information of SCSI adapters on the SCSI bus is set. Press the [F2] key from the
[Main] menu window, select [Adapter] and press the [Enter] key to display the window.
LSI Logic MPT SCSI Setup Utility Version MPT BIOS-IME-n.nn.nn
Adapter
Properties
Adapter
PCI
Bus
1020/1030
2
1020/1030
2
<Device Properties>
<RAID
Properties><Synchronize Whole Mirror>
Host SCSI ID
SCSI Bus Scan Order
Removable Media Support
CHS Mapping
Spinup Delay(Secs)
Secondary Cluster Server
Termination Control
<Restore Defaults>
F1 =HELP
Esc=Abort/Exit
Item
Host SCSI ID
SCSI Bus Scan Order
Removable Media Support
CHS Mapping
Spinup Delay (Secs)
Secondary Cluster Server
Termination Control
Restore Defaults
256
DEV/
Func
40
41
[ 7]
[Low to High(0..Max)]
[None]
[SCSI Plug and Play Mapping]
[ 2]
[No]
[Auto]
ArrowKeys=Select Item
Home/End=Select Item
table: Items on the Adapter Properties Window
Setting
7 (Fixed parameter)
Low to High (0..Max)
(Fixed parameter)
None (Fixed parameter)
SCSI Plug and Play
Mapping (Fixed parameter)
• 2 (at the time of
purchase)
• 1–15
No (Fixed parameter)
Auto (Fixed parameter)
Reads default values for the controller.
-/+ =Change [Item]
Enter=Excute <Item>
Description
Specifies the SCSI ID of the SCSI controller.
Specifies the SCSI bus scan order during the
startup.
Sets whether or not the SCSI BIOS supports
removable disk units such as MO drives.
Specifies the disk mapping method.
Specifies the interval between a server startup and
the start of disk rotation.
Sets whether to enable or disable the secondary
cluster server.
Sets whether to enable or disable the terminator on
the system board.

Advertisement

Table of Contents
loading

Table of Contents