Panasonic WV-U2500 Series Operating Instructions Manual page 20

Table of Contents

Advertisement

1 Operations
If "90 °" or "270 °" is selected for [Image rotation], depending on the [Character size] setting
and the number of characters used, characters displayed on the screen may be cut off.
When [Image rotation] is set to "90 °", "270 °", the position that can be set in [Date/time
position] and [Camera title position] is restricted to "Upper left" and "Lower left".
Note
When [4:3 (30fps mode)] or [4:3 (25fps mode)] is selected for [Image capture mode], "90 °" and
"270 °" cannot be selected for [Image rotation].
When [Image capture size] of any of JPEG(1), JPEG(2), Stream(1), Stream(2) and
Stream(3) is set to "320x180", "90 °" and "270 °" will become unavailable for [Image rotation].
Manual zoom adjustment
Adjust the zoom manually.
[-]: Adjust the zoom (magnification) up to 1.0 time in the "Wide" side.
[´1]: Make the zoom (magnification) 1.0 times.
[+]: Adjust the zoom (magnification) to the "Tele" side.
Note
[WV-U2542L][WV-U2532L][WV-U1542L][WV-U1532L][WV-U2142L][WV-U2132L][WV-U1142]
[WV-U1132]
The camera switches between optical zoom and extra optical zoom depending on the zoom
ratio. The supported optical zoom and extra optical zoom ratios vary depending on the model
and the selected image capture mode.
When "Image capture size" is set to "640x360" or a higher resolution, image quality may
deteriorate depending on the zoom ratio. For further information, refer to our website
(https://security.panasonic.com/training_support/support/info/ <Control No.: C0124>).
[WV-U2540L] [WV-U2530L] [WV-U2140L] [WV-U2130L] [WV-U1130]
The maximum zoom ratio for extra zoom varies depending on the model and the selected
[Image capture mode].
Refer to the Important Information for more information about the maximum zoom ratio.
IMPORTANT
[WV-U2542L][WV-U2532L][WV-U1542L][WV-U1532L][WV-U2142L][WV-U2132L][WV-U1142]
[WV-U1132]
If extra optical zoom is configured after configuring settings for the mask area, privacy zone,
VMD area, SCD area and VIQS area, the configured areas for those settings may move out of
alignment. Therefore, perform the setting for extra optical zoom function before other settings.
[WV-U2540L] [WV-U2530L] [WV-U2140L] [WV-U2130L] [WV-U1130]
The extra zoom function may not be activated on the appropriate position if the setting for the
function is performed after the settings for the VIQS area, privacy zone, or VMD area.
Therefore, configure each area's settings after configuring the extra zoom settings.
Configure mask area settings with a zoom ratio of x1.0. The mask area operates in the mask
position of zoom ratio of x1.0 even after extra zoom settings.
Manual focus adjustment [WV-U2542L][WV-U2532L][WV-U1542L][WV-U1532L][WV-U2142L]
[WV-U2132L][WV-U1142][WV-U1132]
Adjust the focus manually.
[Near]: Adjust the focus in the "near" direction.
[Reset]: Return focus to initial setting.
[Far]: Adjust the focus in the "far" direction.
20
Operating Instructions
Privacy zone
VMD area
SCD area
VIQS area
U153x
U253x
U113x
U213x

Advertisement

Table of Contents
loading

This manual is also suitable for:

Wv-u1500 seriesWv-u2100 seriesWv-u1100 series

Table of Contents