Problem
Position readout is
unrealistic or not
shown.
On-screen display is
not showing correct-
ly after replacing the
monitor.
5.6

Error Messages and Icons

When an error occurs, the system does the following:
• Releases an aural alarm,
• displays the error window at the screen enter, and
• displays the applicable error icon at the bottom-right corner on the screen.
The error window, an example of which is shown below, displays the applicable error
icon, error name, error code, and error remedy.
Error icon
Remedy
When an error occurs, click the [OK] button in the error window to silence the aural
alarm. The error icon remains on the screen until the error is resolved. The error icon
can be clicked to display error content, in the error window. If multiple errors occur si-
multaneously, the error having the highest priority is displayed. The table below shows
the error icon, error name, error code, reason/remedy and priority order for each error
type.
If the error window appears repeatedly, contact a FURUNO dealer to request service.
Error
Error name
Icon
Control Unit
Communication Error
• The cable connected to the navigation equipment is disconnected or dam-
aged. Check the cable, and reconnect or replace it as necessary.
• The navigation equipment is malfunctioning. Check the navigation equip-
ment.
A new monitor must be set up from the [Service] menu. Contact your local
dealer.
Error
code
C01
5. MAINTENANCE AND TROUBLESHOOTING
Reason, remedy
Error name
Error code
If multiple errors occur in the
Processor Unit (Transceiver Unit),
all generated error codes appear.
Reason, remedy
Communication error between the
Trackball Control Unit and the Processor
Unit. Check the connection between the
Trackball Control Unit and Processor
Unit.
5
Priority
Order
1
5-5