Furuno FSS-3BB Operator's Manual page 104

Fish species and biomass sounder
Hide thumbs Also See for FSS-3BB:
Table of Contents

Advertisement

5. MAINTENANCE AND TROUBLESHOOTING
Error
Error name
Icon
Processor Unit
System Error
Transceiver Unit
System Error
5-6
Error
Reason, remedy
code
P01
The voltage of the battery inside the Pro-
cessor Unit is low. Turn the equipment
off, then contact your local dealer to re-
quest replacement of the battery.
P02
The fan is in the Processor Unit is rotat-
ing too slowly. Turn the equipment off,
then contact your local dealer to request
replacement of the fan.
P03
Multiple alike IP addresses found. Turn
the equipment off, then contact your lo-
cal dealer for advice. (IP address setup
cannot be changed from this equipment.
Change the IP address at the external
device.)
T01
Communication error between the
Transceiver Unit and Processor Unit.
Turn the equipment off, then contact
your local dealer for service.
T02
The rotating speed of the fan in the
Transceiver Unit is abnormal. Turn the
equipment off, then contact your local
dealer for service.
T03
Overcurrent detected in the Transceiver
Unit. Turn the equipment off, then con-
tact your local dealer for service.
T04
TX voltage error detected in the Trans-
ceiver Unit. Turn the equipment off, then
contact your local dealer for service.
T06
Transducer connection error (short cir-
cuit) detected. Turn the equipment off,
then contact your local dealer for ser-
vice.
Priority
Order
3
4
5
2
6
7
8
9

Advertisement

Table of Contents
loading

Table of Contents