(continued)
MK1000 will not communicate
over a wired-Ethernet
connection.
Table F-1. Troubleshooting (Continued)
Possible Causes
Troubleshooting
Possible Solutions
3. Confirm the Wired Ethernet
Setup is ENABLED.
- On the Ethernet Configuration
screen (3rd line), Enabled must =
Yes.
- If Enabled = No, with the cursor
on Enabled, press the '4' button.
Enabled should now = Yes. See
Troubleshooting Note 1.
- Press 1 (Network Configuration
screen re-appears).
(continued)
4. Confirm the Wireless (RF)
Ethernet Setup is DISABLED.
- Scroll the cursor down to Wired/
Wireless Ethernet by pressing '3'.
- With the cursor on Wired/Wireless
Ethernet, press '4' (Wired/WIreless
Configuration screen appears).
- On the Wired/Wireless
Configuration screen (3rd line),
Enabled must = No.
-
If Enabled = Yes, with the cursor
on Enabled, press the '4' button.
Enabled should now = No. See
Troubleshooting Note 1.
- Press '1' (Network Configuration
screen re-appears).
- Press '1' (System menu re-
appears).