RS-485 Configuration Screen
From the Driver Configuration menu (see
Next buttons to move the "<" cursor to either the RS-485 Port option and press the Enter
button. To return to the Driver Configuration menu, press the '1' button to escape.
The RS-485 Config screen displays:
The RS-485 Config screen includes the same structure and field definitions as the RS-232
Config screen with a slight difference: RS-485 includes extra Rx modes, and hardware
support exists for 10-bit and 11-bit serial frames (start bit, data bits, parity, stop bits) only.
Field Name
Baud (Rate)
RS-232 Port Configuration
Baud
: 9600 <
Parity: NONE
Data
: 8 BITS
Stops : 1 BIT
Flow
: NONE
Toggles Baud Rate
Figure 3-47. RS-485 Config Screen
Table 3-22. RS-485 Config Screen Definitions
Press the Previous or Next buttons to move the "<"
cursor to this field and toggle by pressing the Enter
button to select the Baud Rate.
The default Baud Rate for MK1000 RS-485 port
settings is 9600.
Available Baud Rates: 110, 300, 600, 1200, 2400,
4800, 9600, 14400, 19200, or 38400.
Setup and Installation: Communication
Figure 3-44 on page
Echo: OFF
Rx
: XPT
Description
3-53), press the Previous or
3-59